Project Settings
Some OpenBridge settings apply to a whole project rather than to one component. They are in the Designer under Project › Project Properties, in the OpenBridge section.
| Page | What it sets |
|---|---|
| Automation Badges | The corner each badge of an automation device sits in, and letters that replace badge symbols. |
| Alerts | Whether red is the highest alert colour, with Medium and Low alerts merged. |
The settings are stored in the project, like Perspective’s own project properties. Click OK or Apply and then save the project (File › Save). OK and Apply only change the Designer’s copy of the project, so the dialog reminds you to save when you change something. Within a few seconds of the save, every open session of the project and the Designer canvas redraw with the new settings.
Automation Badges
Section titled “Automation Badges”The page applies to the automation buttons
(pumps, fans, motors, valves, switches, …). The badge letters also apply to the
Automation Tank, which keeps its badges in a fixed
row, so the badge layout does not change it. The badges
themselves are still set per component, with badgeControl, badgeAlert,
badgeInterlock and badgeCommandLocked. This page only decides where they
sit and what they draw.
Badge Layout
Section titled “Badge Layout”One dropdown per corner: Top left, Top right, Bottom left and Bottom right. Each offers Control, Alert, Interlock, Command locked or Empty, where Empty shows no badge in that corner.
The default is the layout the devices have always had:
| Corner | Default |
|---|---|
| Top left | Control |
| Top right | Alert |
| Bottom left | Interlock |
| Bottom right | Command locked |
A badge can be in one corner only. If two corners name the same badge, the dialog refuses OK / Apply and says which badge is used twice. A badge that is in no corner is not shown, even when its property is set.
Badge Letters
Section titled “Badge Letters”Some installations mark a state with a letter rather than a symbol, for example S for Simulation. Each badge value has a dropdown:
- Symbol (the default) keeps the symbol.
- A to Z draws that letter instead.
| Group | Values |
|---|---|
| Control | Local, Local only, Manual, Manual only, Auto |
| Alert | Silenced, Shelved, Level critical, Level high, Level medium, Level low, Level diagnostic |
| Interlock | Interlock, Interlock inhibit, Simulation |
| Command locked | Command locked, Simulation |
A letter replaces the symbol of one value only. For example, Interlock ›
Simulation = S leaves the Interlock and Interlock inhibit symbols as they are.
none never shows a badge.
Reset to defaults sets every dropdown on the page back to the default layout and the symbols. As with any other change, apply it and save the project.
Example
Section titled “Example”To show Simulation as an S in the bottom-right corner, and to swap the two top badges:
- Set Top left to Alert and Top right to Control.
- Under Command locked, set Simulation to S.
- Click OK and save the project.
A pump with badgeAlert = level-high, badgeControl = auto,
badgeInterlock = interlock and badgeCommandLocked = simulation then
shows the alert top left, the Auto symbol top right, Interlock bottom left and
an S bottom right.
Alerts
Section titled “Alerts”OpenBridge draws five alert levels: Critical in magenta, High in red, Medium in orange, Low in yellow, and Diagnostic. Some sites have no magenta: red is the most serious colour they show. For them, tick Use red as highest alert color, and merge low and medium criticality. It is off by default.
With the box ticked, every component of the project draws alert levels one step down:
| Alert level (Ignition priority) | Off (default) | On |
|---|---|---|
level-critical (Critical) |
magenta | red |
level-high (High), legacy alarm |
red | orange |
level-medium (Medium), warning |
orange | yellow |
level-low (Low), caution |
yellow | yellow |
level-diagnostic (Diagnostic) |
unchanged | unchanged |
This applies everywhere a level is drawn: alert frames (on the automation
devices, the Automation Tank, the Transmitter, the Alert Frame Container, the
Readout and the Readout List Item), alert badges (badgeAlert, the Automation
Badge, the Badge, the Tab Row’s badges), the Top Bar, the alert list, the alert
detail, the alert menus and the connector diagram’s mini-map. Alert counts are
merged the same way: the Top Bar, the Alert Subsystem Button and the Navbar count
Critical as High, High as Medium, and Medium and Low together as Low.
What does not change:
- Acknowledging, filtering and sorting follow the alarm’s own priority. Under the BAM convention a Medium alarm can still be acknowledged, although it is drawn yellow like a Low one. The Top Bar’s counter filter still picks priorities by their Ignition name.
- Text keeps Ignition’s priority names, for example in an alarm’s own label or notes.
- A letter set for a badge value on the Automation Badges page applies to the
level that is drawn: with the box ticked, a Critical alarm’s
badgeAlertdraws aslevel-high, so it shows the letter set for Level high. - Views and tags. The setting only changes how the levels are drawn.
For Integrators
Section titled “For Integrators”The badge settings are a project resource,
no.openstudio.openbridge/project-settings, and the alert setting a second one,
no.openstudio.openbridge/alert-settings; each data.bin holds JSON. The
Gateway serves both together, read-only, at
/data/openbridge/project-settings/<project>, with the alert setting as
alertLevelMapping ("default" or "red-highest"). When the project has no
settings, that URL returns the defaults.
{ "version": 1, "badgeLayout": { "topLeft": "alert", "topRight": "control", "bottomLeft": "interlock", "bottomRight": "command-locked" }, "badgeSymbolOverride": {"commandLocked": {"simulation": "S"}}, "alertLevelMapping": "red-highest"}Found an error or something unclear?